@inproceedings{3ef54027a7bc450bbdef8042bd5142ba,
title = "Transient response enhancement of PFC front end",
abstract = "An enhancement of a conventional PI controller used on grid connected power factor corrector (PFC) systems is suggested in this paper. The transient length is reduced by applying two different methods. The first one consists of an auxiliary unit which increases the error signal, while the second one is a hybrid controller which completely replaces the basic PI controller when DC-link voltage drop is detected. The applied control method is based on hybrid controller proposed in the literature for dc-dc power converters. In order to apply this method to the PCF case the controller was properly analyzed for variable input voltage and simulation results demonstrate the theoretical findings.",
author = "M. Mellincovsky and M. Sitbon and Peretz, {M. M.} and S. Schacham and A. Kuperman",
note = "Publisher Copyright: {\textcopyright} 2017 IEEE.; 25th Mediterranean Conference on Control and Automation, MED 2017 ; Conference date: 03-07-2017 Through 06-07-2017",
year = "2017",
month = jul,
day = "18",
doi = "https://doi.org/10.1109/MED.2017.7984215",
language = "American English",
series = "2017 25th Mediterranean Conference on Control and Automation, MED 2017",
pages = "794--798",
booktitle = "2017 25th Mediterranean Conference on Control and Automation, MED 2017",
}