TY - JOUR
T1 - Superconducting nanowire single-photon sensing of cerebral blood flow
AU - Ozana, Nisan
AU - Zavriyev, Alexander I.
AU - Mazumder, Dibbyan
AU - Robinson, Mitchell
AU - Kaya, Kutlu
AU - Blackwell, Megan
AU - Carp, Stefan A.
AU - Franceschini, Maria Angela
N1 - Publisher Copyright: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
PY - 2021/7/1
Y1 - 2021/7/1
N2 - Significance: The ability of diffuse correlation spectroscopy (DCS) to measure cerebral blood flow (CBF) in humans is hindered by the low signal-to-noise ratio (SNR) of the method. This limits the high acquisition rates needed to resolve dynamic flow changes and to optimally filter out large pulsatile oscillations and prevents the use of large source-detector separations (≥3 cm), which are needed to achieve adequate brain sensitivity in most adult subjects. Aim: To substantially improve SNR, we have built a DCS device that operates at 1064 nm and uses superconducting nanowire single-photon detectors (SNSPD). Approach: We compared the performances of the SNSPD-DCS in humans with respect to a typical DCS system operating at 850 nm and using silicon single-photon avalanche diode detectors. Results: At a 25-mm separation, we detected 13 ± 6 times more photons and achieved an SNR gain of 16 ± 8 on the forehead of 11 subjects using the SNSPD-DCS as compared to typical DCS. At this separation, the SNSPD-DCS is able to detect a clean pulsatile flow signal at 20 Hz in all subjects. With the SNSPD-DCS, we also performed measurements at 35 mm, showing a lower scalp sensitivity of 31 ± 6 % with respect to the 48 ± 8 % scalp sensitivity at 25 mm for both the 850 and 1064 nm systems. Furthermore, we demonstrated blood flow responses to breath holding and hyperventilation tasks. Conclusions: While current commercial SNSPDs are expensive, bulky, and loud, they may allow for more robust measures of non-invasive cerebral perfusion in an intensive care setting.
AB - Significance: The ability of diffuse correlation spectroscopy (DCS) to measure cerebral blood flow (CBF) in humans is hindered by the low signal-to-noise ratio (SNR) of the method. This limits the high acquisition rates needed to resolve dynamic flow changes and to optimally filter out large pulsatile oscillations and prevents the use of large source-detector separations (≥3 cm), which are needed to achieve adequate brain sensitivity in most adult subjects. Aim: To substantially improve SNR, we have built a DCS device that operates at 1064 nm and uses superconducting nanowire single-photon detectors (SNSPD). Approach: We compared the performances of the SNSPD-DCS in humans with respect to a typical DCS system operating at 850 nm and using silicon single-photon avalanche diode detectors. Results: At a 25-mm separation, we detected 13 ± 6 times more photons and achieved an SNR gain of 16 ± 8 on the forehead of 11 subjects using the SNSPD-DCS as compared to typical DCS. At this separation, the SNSPD-DCS is able to detect a clean pulsatile flow signal at 20 Hz in all subjects. With the SNSPD-DCS, we also performed measurements at 35 mm, showing a lower scalp sensitivity of 31 ± 6 % with respect to the 48 ± 8 % scalp sensitivity at 25 mm for both the 850 and 1064 nm systems. Furthermore, we demonstrated blood flow responses to breath holding and hyperventilation tasks. Conclusions: While current commercial SNSPDs are expensive, bulky, and loud, they may allow for more robust measures of non-invasive cerebral perfusion in an intensive care setting.
KW - cerebral blood flow
KW - diffuse correlation spectroscopy
KW - pulsatile blood flow
KW - superconducting nanowire detectors
UR - http://www.scopus.com/inward/record.url?scp=85116479863&partnerID=8YFLogxK
U2 - 10.1117/1.NPh.8.3.035006
DO - 10.1117/1.NPh.8.3.035006
M3 - مقالة
C2 - 34423069
SN - 2329-423X
VL - 8
JO - Neurophotonics
JF - Neurophotonics
IS - 3
M1 - 035006
ER -