Abstract
Point-source atom interferometry is a promising approach for implementing robust, high-sensitivity, rotation sensors using cold atoms. However, its scale factor, i.e., the ratio between the interferometer signal and the actual rotation rate, depends on the initial conditions of the atomic cloud, which may drift in time and result in bias instability, particularly in compact devices with short interrogation times. We present two methods to stabilize the scale factor. One relies on a model-based correction which exploits correlations between multiple features of the interferometer output and works on a single-shot basis. The other is a self-calibrating method where a known bias rotation is applied to every other measurement, requiring no prior knowledge of the underlying model but reducing the sensor bandwidth by a factor of two. We demonstrate both schemes experimentally with complete suppression of scale-factor drifts, maintaining the original rotation sensitivity and allowing for bias-free operation over several hours.
| Original language | English |
|---|---|
| Article number | 013326 |
| Number of pages | 8 |
| Journal | Physical Review A |
| Volume | 102 |
| Issue number | 1 |
| DOIs | |
| State | Published - 29 Jul 2020 |
All Science Journal Classification (ASJC) codes
- Atomic and Molecular Physics, and Optics