TY - GEN
T1 - Redundancy resolution of a human arm for controlling a seven DOF wearable robotic system
AU - Kim, Hyunchul
AU - Miller, Levi Makaio
AU - Al-Refai, Aimen
AU - Brand, Moshe
AU - Rosen, Jacob
PY - 2011
Y1 - 2011
N2 - The human arm including the shoulder, elbow, wrist joints and exclusion scapular motion has 7 Degrees of Freedom (DOF) while positioning of the wrist in space and orientating the palm is a task that requires 6 DOF. As such it includes one more DOF than is needed to complete the task. Given the redundant nature of the arm, multiple arm configurations can be used to complete a task, which is expressed mathematically by none unique solution for the inverse kinematics. Despite this mathematical difficulty, the motor control provides a unique solution for the arm redundancy as the arm is moved in space. Resolving this redundancy is becoming critical as the human interacts with a wearable robotic system(exoskeleton) which includes the same redundancy as the human arm. Therefore, the inverse kinematics solution resolving the redundancy of these two coupled systems must be identical in order to guarantee a seamless integration. The redundancy of the arm can be formulated kinematically by defining the swivel angle the rotation angle of the plane including the upper and lower arm around a virtual axis connecting the shoulder and wrist joints which are fixed in space. Analyzing reaching tasks recorded with a motion capture lab indicates that the swivel angle is selected such that when the elbow joint is flexed, the palm points the head. Based on these experimental results, selecting the point around the center of the head as a stationary target allows to calculate the swivel angle and in that way to resolve the human arm redundancy. Experimental results indicated that by using the proposed redundancy resolution criteria the error between the predicted swivel angle and the actual swivel angle adopted by the motor control system is less then 5 Deg. This criterion or a synthesis of several additional criteria may improve the synergistic relationships between an operator and a wearable robotic system.
AB - The human arm including the shoulder, elbow, wrist joints and exclusion scapular motion has 7 Degrees of Freedom (DOF) while positioning of the wrist in space and orientating the palm is a task that requires 6 DOF. As such it includes one more DOF than is needed to complete the task. Given the redundant nature of the arm, multiple arm configurations can be used to complete a task, which is expressed mathematically by none unique solution for the inverse kinematics. Despite this mathematical difficulty, the motor control provides a unique solution for the arm redundancy as the arm is moved in space. Resolving this redundancy is becoming critical as the human interacts with a wearable robotic system(exoskeleton) which includes the same redundancy as the human arm. Therefore, the inverse kinematics solution resolving the redundancy of these two coupled systems must be identical in order to guarantee a seamless integration. The redundancy of the arm can be formulated kinematically by defining the swivel angle the rotation angle of the plane including the upper and lower arm around a virtual axis connecting the shoulder and wrist joints which are fixed in space. Analyzing reaching tasks recorded with a motion capture lab indicates that the swivel angle is selected such that when the elbow joint is flexed, the palm points the head. Based on these experimental results, selecting the point around the center of the head as a stationary target allows to calculate the swivel angle and in that way to resolve the human arm redundancy. Experimental results indicated that by using the proposed redundancy resolution criteria the error between the predicted swivel angle and the actual swivel angle adopted by the motor control system is less then 5 Deg. This criterion or a synthesis of several additional criteria may improve the synergistic relationships between an operator and a wearable robotic system.
UR - http://www.scopus.com/inward/record.url?scp=84862618532&partnerID=8YFLogxK
U2 - https://doi.org/10.1109/IEMBS.2011.6090938
DO - https://doi.org/10.1109/IEMBS.2011.6090938
M3 - منشور من مؤتمر
C2 - 22255087
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 3471
EP - 3474
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -