Abstract
Real-world bioelectronics applications, including drug delivery systems, biosensing and electrical modulation of tissues and organs, largely require biointerfaces at the macroscopic level. However, traditional macroscale bioelectronic electrodes usually exhibit invasive or power-inefficient architectures, inability to form uniform and subcellular interfaces, or faradaic reactions at electrode surfaces. Here, we develop a micelle-enabled self-assembly approach for a binder-free and carbon-based monolithic device, aimed at large-scale bioelectronic interfaces. The device incorporates a multi-scale porous material architecture, an interdigitated microelectrode layout and a supercapacitor-like performance. In cell training processes, we use the device to modulate the contraction rate of primary cardiomyocytes at the subcellular level to target frequency in vitro. We also achieve capacitive control of the electrophysiology in isolated hearts, retinal tissues and sciatic nerves, as well as bioelectronic cardiac sensing. Our results support the exploration of device platforms already used in energy research to identify new opportunities in bioelectronics.
| Original language | English |
|---|---|
| Pages (from-to) | 206-213 |
| Number of pages | 8 |
| Journal | Nature Nanotechnology |
| Volume | 16 |
| Issue number | 2 |
| DOIs | |
| State | Published - 1 Feb 2021 |
| Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Bioengineering
- Atomic and Molecular Physics, and Optics
- Biomedical Engineering
- General Materials Science
- Condensed Matter Physics
- Electrical and Electronic Engineering