Abstract
Particle picking is currently a critical step in the cryo-EM single particle reconstruction pipeline. Despite extensive work on this problem, for many data sets it is still challenging, especially for low SNR micrographs. We present the KLT (Karhunen Loeve Transform) picker, which is fully automatic and requires as an input only the approximated particle size. In particular, it does not require any manual picking. Our method is designed especially to handle low SNR micrographs. It is based on learning a set of optimal templates through the use of multi-variate statistical analysis via the Karhunen Loeve Transform. We evaluate the KLT picker on publicly available data sets and present high-quality results with minimal manual effort.
| Original language | English |
|---|---|
| Article number | 107473 |
| Journal | Journal of Structural Biology |
| Volume | 210 |
| Issue number | 2 |
| DOIs | |
| State | Published - 1 May 2020 |
Keywords
- Cryo-electron microscopy
- Karhunen Loeve Transform
- Particle picking
- Single-particle reconstruction
ASJC Scopus subject areas
- Structural Biology
Fingerprint
Dive into the research topics of 'KLT picker: Particle picking using data-driven optimal templates'. Together they form a unique fingerprint.Cite this