Influence of Single Stent Size and Tandem Stents Subject to Extrinsic Ureteral Obstruction and Stent Occlusion on Stent Failure

Tal Amitay-Rosen, Yaniv Shilo, Ishai Dror, Brian Berkowitz

Research output: Contribution to journalArticlepeer-review

Abstract

Drainage of obstructed kidney attributable to extrinsic ureteral obstruction (EUO), required to prevent renal damage, is often achieved using Double-J ureteral stents. However, these stents fail frequently, and there is considerable debate regarding what stent size, type, and configuration offer the best option for sustained drainage. In this study, we examine the impact of stent diameter and choice of single/tandem configuration, subject to EUO and various degrees of stent occlusion, on stent failure.
Computational fluid dynamics simulations and an
ureter-stent experiment enabled quantification of flow behavior in stented ureters subject to EUO and stent occlusions. Various single and tandem stents under EUO were considered. In each simulation and experiment, changes in renal pressure were monitored for different degrees of stent lumen occlusion, and onset of stent failure as well as simulated distributions of fluid flow between stent and ureter lumina were determined.
For an encircling EUO that completely obstructs the ureter lumen, with or without partial stent occlusion, the choice of stent size/configuration has little effect on renal pressure. The pressure increases significantly for ∼90% stent lumen occlusion, with failure at >95% occlusion, independent of stent diameter or a tandem configuration, and with little influence of occlusion length along the stent.
Stent failure rate is independent of stent diameter or single/tandem configuration, for the same percentage of stent lumen occlusion, in this model. Stent failure incidence may decrease for larger diameter stents and tandem configurations, because of the larger luminal area.
Original languageEnglish
Pages (from-to)236-242
Number of pages7
JournalJournal of Endourology
Volume36
Issue number2
DOIs
StatePublished - 1 Feb 2022

Fingerprint

Dive into the research topics of 'Influence of Single Stent Size and Tandem Stents Subject to Extrinsic Ureteral Obstruction and Stent Occlusion on Stent Failure'. Together they form a unique fingerprint.