TY - GEN
T1 - Improved multi B-value diffusion-weighted MRI of the body by Simultaneous Model Estimation and Image Reconstruction (SMEIR)
AU - Freiman, Moti
AU - Afacan, Onur
AU - Mulkern, Robert V.
AU - Warfield, Simon K.
N1 - Funding Information: This investigation is supported in part by NIH grants R01 LM010033 R42 MH086984 R01 EB008015 UL1 TR000170 and by research grants from the Translational Research Program at Boston Children’s Hospital. M.F is also supported in part by a Research Fellow Award from the Crohn’s and Colitis Foundation of America.
PY - 2013
Y1 - 2013
N2 - Diffusion-weighted MRI images acquired with multiple b-values have the potential to improve diagnostic accuracy by increasing the conspicuity of lesions and inflammatory activity with background suppression. Unfortunately, the inherently low signal-to-noise ratio (SNR) of DW-MRI reduces enthusiasm for using these images for diagnostic purposes. Moreover, lengthy acquisition times limit our ability to improve the quality of multi b-value DW-MRI images by multiple excitations acquisition and signal averaging at each b-value. To offset these limitations, we propose the Simultaneous Model Estimation and Image Reconstruction (SMEIR) for DW-MRI, which substantially improves the quality of multi b-value DW-MRI images without increasing acquisition times. Our model introduces the physiological signal decay model of DW-MRI as a constraint in the reconstruction of the DW-MRI images. An in-vivo experiment using 6 low-quality DW-MRI datasets of a healthy subject showed that SMEIR reconstruction of low-quality data improved SNR by 55% in the liver and by 41% in the kidney without increasing acquisition times. We also demonstrated the clinical impact of our SMEIR reconstruction by increasing the conspicuity of inflamed bowel regions in DW-MRI of 12 patients with Crohn's disease. The contrast-to-noise ratio (CNR) of the inflamed regions in the SMEIR images was higher by 12.6% relative to CNR in the original DW-MRI images.
AB - Diffusion-weighted MRI images acquired with multiple b-values have the potential to improve diagnostic accuracy by increasing the conspicuity of lesions and inflammatory activity with background suppression. Unfortunately, the inherently low signal-to-noise ratio (SNR) of DW-MRI reduces enthusiasm for using these images for diagnostic purposes. Moreover, lengthy acquisition times limit our ability to improve the quality of multi b-value DW-MRI images by multiple excitations acquisition and signal averaging at each b-value. To offset these limitations, we propose the Simultaneous Model Estimation and Image Reconstruction (SMEIR) for DW-MRI, which substantially improves the quality of multi b-value DW-MRI images without increasing acquisition times. Our model introduces the physiological signal decay model of DW-MRI as a constraint in the reconstruction of the DW-MRI images. An in-vivo experiment using 6 low-quality DW-MRI datasets of a healthy subject showed that SMEIR reconstruction of low-quality data improved SNR by 55% in the liver and by 41% in the kidney without increasing acquisition times. We also demonstrated the clinical impact of our SMEIR reconstruction by increasing the conspicuity of inflamed bowel regions in DW-MRI of 12 patients with Crohn's disease. The contrast-to-noise ratio (CNR) of the inflamed regions in the SMEIR images was higher by 12.6% relative to CNR in the original DW-MRI images.
UR - http://www.scopus.com/inward/record.url?scp=84885906603&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-40760-4_1
DO - 10.1007/978-3-642-40760-4_1
M3 - منشور من مؤتمر
C2 - 24505737
SN - 9783642407598
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 1
EP - 8
BT - Medical Image Computing and Computer-Assisted Intervention, MICCAI 2013 - 16th International Conference, Proceedings
T2 - 16th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2013
Y2 - 22 September 2013 through 26 September 2013
ER -