TY - JOUR
T1 - Hyperpolarized choline as an MR imaging molecular probe
T2 - Feasibility of in vivo imaging in a rat model
AU - Friesen-Waldner, Lanette J.
AU - Wade, Trevor P.
AU - Thind, Kundan
AU - Chen, Albert P.
AU - Gomori, J. Moshe
AU - Sosna, Jacob
AU - McKenzie, Charles A.
AU - Katz-Brull, Rachel
N1 - Publisher Copyright: © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
PY - 2015/4/1
Y1 - 2015/4/1
N2 - Purpose To assess the feasibility of choline MRI using a new choline molecular probe for dynamic nuclear polarization (DNP) hyperpolarized MRI. Materials and Methods Male Sprague-Dawley rats with an average weight of 400 ± 20 g (n = 5), were anesthetized and injection tubing was placed in the tail vein. [1,1,2,2-D4, 1-13C]choline chloride (CMP1) was hyperpolarized by DNP and injected into rats at doses ranging from 12.6 to 50.0 mg/kg. Coronal projection 13C imaging was performed on a 3 Tesla clinical MRI scanner (bore size 60 cm) using a variable flip angle gradient echo sequence. Images were acquired 15 to 45 s after the start of bolus injection. Signal intensities in regions of interest were determined at each time point and compared. Results 13C MRI images of hyperpolarized CMP1 at a 50 mg/kg dose showed time-dependent organ distribution patterns. At 15 s, high intensities were observed in the inferior vena cava, heart, aorta, and kidneys. At 30 s, most of the signal intensity was localized to the kidneys. These distribution patterns were reproduced using 12.6 and 25 mg/kg doses. At 45 s, only signal in the kidneys was detected. Conclusion Hyperpolarized choline imaging with MRI is feasible using a stable-isotope labeled choline analog (CMP1). Nonradioactive imaging of choline accumulation may provide a new investigatory dimension for kidney physiology.
AB - Purpose To assess the feasibility of choline MRI using a new choline molecular probe for dynamic nuclear polarization (DNP) hyperpolarized MRI. Materials and Methods Male Sprague-Dawley rats with an average weight of 400 ± 20 g (n = 5), were anesthetized and injection tubing was placed in the tail vein. [1,1,2,2-D4, 1-13C]choline chloride (CMP1) was hyperpolarized by DNP and injected into rats at doses ranging from 12.6 to 50.0 mg/kg. Coronal projection 13C imaging was performed on a 3 Tesla clinical MRI scanner (bore size 60 cm) using a variable flip angle gradient echo sequence. Images were acquired 15 to 45 s after the start of bolus injection. Signal intensities in regions of interest were determined at each time point and compared. Results 13C MRI images of hyperpolarized CMP1 at a 50 mg/kg dose showed time-dependent organ distribution patterns. At 15 s, high intensities were observed in the inferior vena cava, heart, aorta, and kidneys. At 30 s, most of the signal intensity was localized to the kidneys. These distribution patterns were reproduced using 12.6 and 25 mg/kg doses. At 45 s, only signal in the kidneys was detected. Conclusion Hyperpolarized choline imaging with MRI is feasible using a stable-isotope labeled choline analog (CMP1). Nonradioactive imaging of choline accumulation may provide a new investigatory dimension for kidney physiology.
KW - choline
KW - magnetic resonance imaging
KW - metabolism
UR - http://www.scopus.com/inward/record.url?scp=84925254232&partnerID=8YFLogxK
U2 - https://doi.org/10.1002/jmri.24659
DO - https://doi.org/10.1002/jmri.24659
M3 - مقالة
C2 - 24862837
SN - 1053-1807
VL - 41
SP - 917
EP - 923
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 4
ER -