Abstract
Calcific aortic valve disease (CAVD) is characterized by calcification accumulation and thickening of the aortic valve cusps, leading to stenosis. The importance of fluid flow shear stress in the initiation and regulation of CAVD progression is well known and has been studied recently using fluid–structure interaction (FSI) models. While cusp calcifications are three-dimensional (3D) masses, previously published FSI models have represented them as either stiffened or thickened two-dimensional (2D) cusps. This study investigates the hemodynamic effect of these calcifications employing FSI models using 3D patient-specific calcification masses. A new reverse calcification technique (RCT) is used for modeling different stages of calcification growth based on the spatial distribution of calcification density. The RCT is applied to generate the 3D calcification deposits reconstructed from a patient-specific CT scans. Our results showed that consideration of 3D calcification deposits led to both higher fluid shear stresses and unique fluid shear stress distribution on the aortic side of the cusps that may have an impact on the calcification growth rate. However, the flow did not seem to affect the geometry of the calcification during the growth phase.
Original language | English |
---|---|
Pages (from-to) | 1683-1694 |
Number of pages | 12 |
Journal | Medical and Biological Engineering and Computing |
Volume | 54 |
Issue number | 11 |
DOIs | |
State | Published - 1 Nov 2016 |
Keywords
- Aortic valve
- Calcification
- Flow
- Fluid–structure interaction
- Hemodynamics
- Stenosis
All Science Journal Classification (ASJC) codes
- Biomedical Engineering
- Computer Science Applications