TY - JOUR
T1 - Curved planar reformatting and convolutional neural network-based segmentation of the small bowel for visualization and quantitative assessment of pediatric Crohn's disease from MRI
AU - Lamash, Yechiel
AU - Kurugol, Sila
AU - Freiman, Moti
AU - Perez-Rossello, Jeannette M.
AU - Callahan, Michael J.
AU - Bousvaros, Athos
AU - Warfield, Simon K.
N1 - Funding Information: This investigation was supported in part by NIH grants R01 NS079788, R01 EB019483, R01 DK100404, R44 MH086984, IDDRC U54 HD090255, and by a research grant from the Boston Children's Hospital Translational Research Program. Funding Information: Contract grant sponsor: Crohn’s and Colitis Foundation of America's Career Development Award; Contract grant sponsor: AGA-Boston Scientific Technology & Innovation Pilot Research Award; Contract grant sponsor: National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) of the NIH; Contract grant number: R01DK100404. Publisher Copyright: © 2018 International Society for Magnetic Resonance in Medicine
PY - 2019/6
Y1 - 2019/6
N2 - Background: Contrast-enhanced MRI of the small bowel is an effective imaging sequence for the detection and characterization of disease burden in pediatric Crohn's disease (CD). However, visualization and quantification of disease burden requires scrolling back and forth through 3D images to follow the anatomy of the bowel, and it can be difficult to fully appreciate the extent of disease. Purpose: To develop and evaluate a method that offers better visualization and quantitative assessment of CD from MRI. Study Type: Retrospective. Population: Twenty-three pediatric patients with CD. Field Strength/Sequence: 1.5T MRI system and T 1 -weighted postcontrast VIBE sequence. Assessment: The convolutional neural network (CNN) segmentation of the bowel's lumen, wall, and background was compared with manual boundary delineation. We assessed the reproducibility and the capability of the extracted markers to differentiate between different levels of disease defined after a consensus review by two experienced radiologists. Statistical Tests: The segmentation algorithm was assessed using the Dice similarity coefficient (DSC) and boundary distances between the CNN and manual boundary delineations. The capability of the extracted markers to differentiate between different disease levels was determined using a t-test. The reproducibility of the extracted markers was assessed using the mean relative difference (MRD), Pearson correlation, and Bland–Altman analysis. Results: Our CNN exhibited DSCs of 75 ± 18%, 81 ± 8%, and 97 ± 2% for the lumen, wall, and background, respectively. The extracted markers of wall thickness at the location of min radius (P = 0.0013) and the median value of relative contrast enhancement (P = 0.0033) could differentiate active and nonactive disease segments. Other extracted markers could differentiate between segments with strictures and segments without strictures (P < 0.05). The observers' agreement in measuring stricture length was >3 times superior when computed on curved planar reformatting images compared with the conventional scheme. Data Conclusion: The results of this study show that the newly developed method is efficient for visualization and assessment of CD. Level of Evidence: 4. Technical Efficacy: Stage 2. J. Magn. Reson. Imaging 2019;49:1565–1576.
AB - Background: Contrast-enhanced MRI of the small bowel is an effective imaging sequence for the detection and characterization of disease burden in pediatric Crohn's disease (CD). However, visualization and quantification of disease burden requires scrolling back and forth through 3D images to follow the anatomy of the bowel, and it can be difficult to fully appreciate the extent of disease. Purpose: To develop and evaluate a method that offers better visualization and quantitative assessment of CD from MRI. Study Type: Retrospective. Population: Twenty-three pediatric patients with CD. Field Strength/Sequence: 1.5T MRI system and T 1 -weighted postcontrast VIBE sequence. Assessment: The convolutional neural network (CNN) segmentation of the bowel's lumen, wall, and background was compared with manual boundary delineation. We assessed the reproducibility and the capability of the extracted markers to differentiate between different levels of disease defined after a consensus review by two experienced radiologists. Statistical Tests: The segmentation algorithm was assessed using the Dice similarity coefficient (DSC) and boundary distances between the CNN and manual boundary delineations. The capability of the extracted markers to differentiate between different disease levels was determined using a t-test. The reproducibility of the extracted markers was assessed using the mean relative difference (MRD), Pearson correlation, and Bland–Altman analysis. Results: Our CNN exhibited DSCs of 75 ± 18%, 81 ± 8%, and 97 ± 2% for the lumen, wall, and background, respectively. The extracted markers of wall thickness at the location of min radius (P = 0.0013) and the median value of relative contrast enhancement (P = 0.0033) could differentiate active and nonactive disease segments. Other extracted markers could differentiate between segments with strictures and segments without strictures (P < 0.05). The observers' agreement in measuring stricture length was >3 times superior when computed on curved planar reformatting images compared with the conventional scheme. Data Conclusion: The results of this study show that the newly developed method is efficient for visualization and assessment of CD. Level of Evidence: 4. Technical Efficacy: Stage 2. J. Magn. Reson. Imaging 2019;49:1565–1576.
KW - Crohn's disease
KW - MRI
KW - convolutional neural network (CNN)
KW - curved planar reformatting (CPR)
UR - https://www.scopus.com/pages/publications/85055580629
U2 - 10.1002/jmri.26330
DO - 10.1002/jmri.26330
M3 - Article
SN - 1053-1807
VL - 49
SP - 1565
EP - 1576
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 6
ER -