Using eco-indicator 99 and a two-stage nested analysis of variance test to evaluate building mitigation measures under hazard risks

نتاج البحث: نشر في مجلةمقالةمراجعة النظراء

ملخص

The study deals with life cycle assessment evaluation of mitigation measures for sustainable structural performance under earthquakes. A case study building using four different mitigation measures was evaluated. To analyze the mitigation measures, CO2 emissions, and environmental damages, six methodological options of Eco-indicator 99 addressing life cycle assessment uncertainties are employed. To compare the mitigation measures, a two-stage nested mixed balanced analysis of variance test is used. Three natural ground motion records were used for analysis. Percentages of the new environmental impact compared to the total building impact were obtained for each mitigation measure under the considered earthquakes. The results obtained on the Eco-indicator 99 damage evaluation level were not consistent with those on the CO2 emission. Along with the results of CO2 emission level, the Eco-indicator 99 damage level results should be disclosed by building designers and practitioners in the design process of mitigation measures.

اللغة الأصليةالإنجليزيّة
الصفحات (من إلى)860-870
عدد الصفحات11
دوريةAdvances in Structural Engineering
مستوى الصوت19
رقم الإصدار5
المعرِّفات الرقمية للأشياء
حالة النشرنُشِر - مايو 2016

All Science Journal Classification (ASJC) codes

  • !!Civil and Structural Engineering
  • !!Building and Construction

بصمة

أدرس بدقة موضوعات البحث “Using eco-indicator 99 and a two-stage nested analysis of variance test to evaluate building mitigation measures under hazard risks'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا